GENERAL
Sound pressure level
< 70 dB
Working temperature
10 – 35 °C
Storage temperature
-25 / 60 °C
Humidity
20-80% RH
Installation category
Category P (according to IEC 1010)
Pollution degree
Degree 2 (according to IEC 1010)
Sample capacity
96 vials of 1.5 ml (STD), 12 vials per segment
72 vials of 4.0 ml (LSV), 9 vials per segment
48 vials of 10ml (Super LSV), 4 vials per segment
160 micro vials of 0.5 ml, 20 vials per segment
Vial dimensions
Maximum vial height: 47 mm inclusive cap.
Minimum vial height: 32 mm inclusive cap.
Loop volume
5 – 1000 µl
Injection volume
1µl – 1 ml, with 1 µl increment
Injections per vial
max. 9 (Volumes are programmable for each
injection)
Injection methods
Flushed loop injections
Partial loopfill injections
µl pick-up injections (without sample loss)
Needle wash
Programmable:
Wash between injections
Wash between vials
Wash at end of series
Wash solvent
250 ml internal wash solvent bottle
Dispenser syringe
100 µl, 250 µl (standard), 500 µl ,1000 µl
or 10ml (only with userprog)
Vial detection
Missing vial detection by vial sensor
Sample access
< 10 seconds
Headspace pressure
Built-in compressor
Pre-puncturing septa
With air needle, dual needle action
Switching time injection valve
electrically < 100 msec
Piercing precision needle
± 0.6 mm
Priority sample
Free programmable
ANALYTICAL PERFORMANCE
Reproducibility
Capped and sealed vials
•Full loop injections
RSD£ 0.3%
•Partial loopfill injections
RSD£ 0.5% injection volumes > 5 µl, with
headspace pressure on the vial and 30µl
pre-flush with air-segment
•µl pick-up injections
RSD£ 1.0% injection volumes > 5 µl, with
headspace pressure on the vial
ELECTRICAL
Power requirements
115 VAC; ±10%; 50/60 Hz; 250 VA
230 VAC; ±10%; 50/60 Hz; 250 VA
Fuses
For 115 VAC; two 5.0 AT-fuses
(slow, ¼” x 1¼”, UL/CSA)
For 230 VAC; two 2.5 AT-fuses
(slow, 5 x 20 mm, IEC127)
COMMUNICATION
Outputs
Inject marker (Relay & TTL)
Vial marker (Relay & TTL)
Labelled vial marker(Relay & TTL)
Stop I/O (Relay & TTL)
BCD output (TTL)
4 Auxiliary outputs (Relay)
2 Programmable outputs (Relay)
Alarm output (Relay)
4 bit time base (TTL)
Inputs
Next injection input (TTL)
Next vial input (TTL)
Freeze input (TTL)
Stop I/O (TTL)
4 programmable inputs (TTL)
Serial communication port
RS 232C or Multilink
Shipping
Shipping options vary by item. Much of our inventory is too big to ship via any method but freight. For smaller individual items (valves, sensors, fittings, etc), Fed Ex, UPS, or USPS will be used. We use eBay's International Shipping Program when needed.
Payment
We only accept Paypal.
Please contact us if you have any questions.
Service
Disclaimers
If you are not satisfied with your purchase for any reason, please let us know within 30 days of receipt in order to return the item. Equipment is located in our warehouse in Wichita, Kansas. Shipping measurements and shipping weight are estimated to the best of our knowledge. In most circumstances, the item pictured will be the item you receive. We may use stock photos on listings with multiple items available for sale. Equipment licenses are not transferable.